Equation (1) defines system-level clamping voltage as VCL ≈ VBR + IPP × RDYN + IParasitic × (dIPP/dt), where IPP is the peak pulse current during an ESD event and IParasitic is the parasitic inductance of the trace from the connector through the TVS to ground. The TPD2E2U06 dual-channel ESD protection device provides ±25 kV contact and ±30 kV air-gap IEC 61000-4-2 Level 4 protection, 5.5-A peak pulse current (8/20 µs), 1.5 pF typical IO capacitance, 6.5 V minimum DC breakdown voltage, and 10 nA maximum leakage current. In an 8 kV ESD event as specified by IEC 61000-4-2, dIESD/dt = (30 A)/(0.8×10-9 s) = 4 × 1010 A/s, so even with 0.25 nH of inductance an additional 10 V is presented to the system.

IEC 61000-4-2 Stress Model and Clamping Voltage Selection

Part 4-2 of IEC 61000 has the status of a basic EMC publication in accordance with IEC Guide 107, and its third edition cancels and replaces the second edition published in 2008. The ESD immunity standard excludes tests intended to evaluate the ESD sensitivity of devices during handling and packaging, and is not intended for characterizing ESD protection circuit performance. Published on 2025-03-07 as Edition 3.0 under ICS 33.100.20, the standard has a stability date of 2027, ISBN number 9782832702581, and 163 pages. In IEC 61000-4-2 testing, testing is performed by charging a 150-pF discharge capacitor and discharging it through a 330-Ω resistor into the strike tip, while two 470-kΩ resistors connect the horizontal coupling plane (HCP) to the ground reference plane (GRP).

In Table 1 for contact discharge, the first peak current tolerance is ±15%, rise time tr tolerance is ±25%, and current tolerances at 30 ns and 60 ns are ±30%. Contact discharge Level 1 specifies 2 kV, 7.5 A first peak current, 0.8 ns rise time, 4 A at 30 ns, and 2 A at 60 ns. Contact discharge Level 2 specifies 4 (kV), 15 (A first peak current), 0.8 (ns rise time), 8 A at 30 ns, and 4 A at 60 ns. Contact discharge Level 3 specifies 6 (kV), 22.5 (A first peak current), 0.8 (ns rise time), 12 A at 30 ns, and 6 A at 60 ns. Contact discharge Level 4 specifies 8 (kV), 30 (A first peak current), 0.8 (ns rise time), 16 A at 30 ns, and 8 A at 60 ns. For the most severe level (level 4), the fast rise time of this waveform induces a dI/dt theoretically from 24 A/ns up to 40 A/ns and typically 30 A/ns.

ESD Test Level or Model Comparison Voltage, Peak Current, and Rise Time Interval Current or Model Comparison
Contact discharge Level 1 specifies 2 kV, 7.5 A first peak current, 0.8 ns rise time 4 A at 30 ns, and 2 A at 60 ns.
Contact discharge Level 2 specifies 4 (kV), 15 (A first peak current), 0.8 (ns rise time) 8 A at 30 ns, and 4 A at 60 ns.
Contact discharge Level 3 specifies 6 (kV), 22.5 (A first peak current), 0.8 (ns rise time) 12 A at 30 ns, and 6 A at 60 ns.
Contact discharge Level 4 specifies 8 (kV), 30 (A first peak current), 0.8 (ns rise time) 16 A at 30 ns, and 8 A at 60 ns.
In Table 2, at an applied 2 kV peak current is 1.33 A for HBM, ~5 A for CDM, and 7.5 A for the IEC 61000-4-2 model while rise time is 25 ns for HBM, < 400 ps for CDM, and < 1 ns for the IEC model.

In Table 2, at an applied 2 kV, peak current is 1.33 A for HBM, ~5 A for CDM, and 7.5 A for the IEC 61000-4-2 model, while rise time is 25 ns for HBM, < 400 ps for CDM, and < 1 ns for the IEC model. The HBM requires only a single positive and single negative strike to be tested, whereas the IEC model requires ten positive strikes and ten negative strikes. In Figure 3, an 8 kV IEC 61000-4-2 waveform has a 30 A spike and a 0.7 ns rise time, whereas an 8kV HBM waveform is much lower and slower. In Table 4-6, ISO 10605 automotive ESD testing uses coupling networks of C = 150 pF; R = 330 Ω and C = 330 pF; R = 330 Ω (up to ±30000 V contact and air-gap discharge), where the 330-pF, 330-Ω test has the highest current flow that needs to be shunted to ground.

Multi-layer PCB assembly showing connector headers, discrete surface-mount protection components, and fine-pitch IC packages
Contact discharge Level 4 specifies 8 (kV), 30 (A first peak current), 0.8 (ns rise time), 16 A at 30 ns, and 8 A at 60 ns.

Breakdown Voltage, Dynamic Resistance, and TLP Clamping Math

When selecting a TVS breakdown voltage (VBR), if the maximum working voltage VRWM on the protected I/O line is 5 V, the TVS should not enter its breakdown region before reaching 5 V, or VBR(min) can be chosen a couple of volts higher than VRWM. At point A, the peak overvoltage during ESD surge current IPP follows Equations (2) and (3): VA = VCL + (dIPP/dt) * (L(TVS path) + LGND), where VCL = VBR + RD * IPP. The industry’s current standard value for dynamic resistance RDYN is 1 Ω or less; Figure 6 shows the TPD1E10B06’s RDYN, which has a typical value of ~0.3 Ω (plotted as RDYN = 0.32 Ω).

Correlating TLP current with IEC 61000-4-2 ESD strikes: a 2kV IEC strike = 4A TLP, a 4kV IEC strike = 8A TLP, a 6kV IEC strike = 12A TLP, and an 8kV IEC strike = 16A TLP; for the ESD122 (Figure 2), clamping voltage is ~13.5V for approximately 100ns during an 8kV IEC strike. Typically, TLP testing involves a rectangular current pulse of 1 to 5-ns rise time and 100-ns pulse width; in the ESD2CANFD24 example, at 16-A the clamping voltage is estimated to be 36-V with snap-back.

Junction Capacitance Budgets Across High-Speed and Industrial Interfaces

In Section 4.9.6 (Figure 4-9), insertion loss measures the power loss or signal strength loss when an ESD device is inserted into a circuit; usually the device supports the signal speed between the 0 and -3-dB range, and the ESD341 example supports up to 5-GHz. The TPDxE05U06 family provides IEC 61000-4-2 level 4 ESD protection (±12kV contact, ±15kV air gap), 80A (5/50ns) EFT protection, 2.5A (8/20µs) surge protection, 0.42pF to 0.5pF typical IO capacitance, and 6.5V minimum DC breakdown voltage. Typical applications for TPDxE05U06 include high speed signal lines in HDMI 1.4b, HDMI 2.0, USB 3.0, MHL, LVDS, DisplayPort, PCI-Express, eSata, and V-by-One HS. The TPD1E10B06 single-channel ESD diode offers ±30kV contact and ±30kV air-gap IEC 61000-4-2 level 4 protection, 6A (8/20µs) surge protection, 12pF typical I/O capacitance, 0.4Ω typical RDYN, ±6V minimum DC breakdown voltage, and 10V maximum clamping voltage at IPP = 1A.

The onsemi ESDM1021 bidirectional ESD protection diode comes in a compact 01005 package measuring 0.445mm x 0.24mm x 0.18mm for circuits with limited PCB space. The Texas Instruments ESD2CANFD24W-Q1 automotive bidirectional two-channel ESD protection diode protects CANH and CANL bus lines from electrostatic discharge and other transients using a compact DFN1110-3 package with wettable flanks.

Commercial ESD Protection Device Protection Rating, Surge Current, and Package Capacitance, Breakdown, and Clamping Characteristics
The TPDxE05U06 family provides IEC 61000-4-2 level 4 ESD protection (±12kV contact, ±15kV air gap), 80A (5/50ns) EFT protection, 2.5A (8/20µs) surge protection 0.42pF to 0.5pF typical IO capacitance, and 6.5V minimum DC breakdown voltage.
The TPD2E2U06 dual-channel ESD protection device provides ±25 kV contact and ±30 kV air-gap IEC 61000-4-2 Level 4 protection, 5.5-A peak pulse current (8/20 µs) 1.5 pF typical IO capacitance, 6.5 V minimum DC breakdown voltage, and 10 nA maximum leakage current.
The TPD1E10B06 single-channel ESD diode offers ±30kV contact and ±30kV air-gap IEC 61000-4-2 level 4 protection, 6A (8/20µs) surge protection, 12pF typical I/O capacitance 0.4Ω typical RDYN, ±6V minimum DC breakdown voltage, and 10V maximum clamping voltage at IPP = 1A.
The TPD3F303 integrates a three-channel C-R-C low-pass EMI filter (47-Ω clock termination resistor, 100-Ω data and reset termination resistors, -3-dB bandwidth 300 MHz) with ±15-kV contact and ±15-kV air-gap IEC 61000-4-2 Level 4 ESD protection and 6 V minimum DC breakdown voltage.
The onsemi ESDM1021 bidirectional ESD protection diode comes in a compact 01005 package measuring 0.445mm x 0.24mm x 0.18mm for circuits with limited PCB space.
The Texas Instruments ESD2CANFD24W-Q1 automotive bidirectional two-channel ESD protection diode protects CANH and CANL bus lines from electrostatic discharge and other transients using a compact DFN1110-3 package with wettable flanks.
Embedded circuit board with external USB, HDMI, and Ethernet connectors and adjacent surface-mount protection components
The TPDxE05U06 family provides IEC 61000-4-2 level 4 ESD protection (±12kV contact, ±15kV air gap), 80A (5/50ns) EFT protection, 2.5A (8/20µs) surge protection, 0.42pF to 0.5pF typical IO capacitance, and 6.5V minimum DC breakdown voltage.

Capacitive Load Limits on Multi-Drop I2C Buses

In TI Table 2-1 for I2C bus modes, the maximum rise time of SDA and SCL is 1000 ns (Standard-mode), 300 ns (Fast-mode), and 120 ns (Fast-mode Plus), while the maximum capacitive load Cb is 400 pF (Standard-mode), 400 pF (Fast-mode), and 550 pF (Fast-mode Plus). Applying equation (6) to the Fast-mode maxima in Table 2-1 (300 ns and 400 pF) causes the pull-up ceiling to fall to 885 Ω, which sits below the 966.667 Ω floor at 3.3 V and 3 mA.

PCB Placement, Parasitic Inductance, and Return-Path Routing

The voltage presented to the node Protected Line is VESD = Vbr(TVS) + IESD * RDYN(TVS) + (L2 + L3)(dIESD/dt), so the PCB designer needs to minimize L3 and eliminate L2. IESD can be steered towards the TVS by making L4 much larger than L1 (L4 >> L1), accomplished by placing the TVS as near to the ESD Source as PCB design rules allow while placing the Protected IC far away. Evaluated at 1nH best-in-class PCB parasitic inductance, peak clamping voltage is 56 V; with added parasitic inductances of 0.6 nH, 1 nH, and 5 nH, peak voltage equals 72 V, 89 V, and 238 V.

Ring-light inspection view of PCB edge connector pads, surface-mount components, ground vias, and copper traces routing to a QFP IC
Evaluated at 1nH best-in-class PCB parasitic inductance, peak clamping voltage is 56 V; with added parasitic inductances of 0.6 nH, 1 nH, and 5 nH, peak voltage equals 72 V, 89 V, and 238 V.

Trace Corners, Via Placement, BGA Ground Vias, and Stackup Bypass

In Figure 2-3, for a 90° corner, the corner is a strong source of EMI where the electric field at the corner is at least 7 kV, leading to an electric arc (ionization) for any radius less than about 2.6 mm in air, whereas 45° and curved corners are much less pronounced. In Case 1, there is no VIA between the ESD Source and the TVS so IESD is forced to the TVS protection pin before the VIA (representing L4 in Figure 2-1), whereas in Case 2 the VIA represents L2 and increases voltage at the Protected IC by LVIA(dIESD/dt). With L2 eliminated (Figure 2-7), the voltage presented to the Protected IC during an ESD event is VESD = Vbr(TVS) + IESD * RDYN(TVS) + L3(dIESD/dt), where for 8 kV, dIESD/dt = 4 × 1010. In Figure 2-9 for a 0.4 mm pitch BGA TVS package with an isolated ground pin, the GND VIA uses a 0.254 mm (10 mil) pad and a 0.152 mm (6 mil) drill (epoxy filled and plated) with a 0.1 mm (4 mil) clearance from VIA to copper.

In Table 3-1, an exposed thermal pad (EP) lowers impedance to ground to help dissipate large ESD currents, though some bidirectional TVS devices require the thermal pad to be floating; for a VCC pin, a 0.1-µF ceramic capacitor is recommended between the VCC trace and the VCC pin on the diode. In a four-layer PCB stackup, placing the power plane next to the ground plane creates additional high-frequency bypass capacitance of approximately 100pF/in2.

Co-Designing ESD Diodes, Surge Protection Devices, and EMI Filters

In IEC 61000-4-4 EFT testing (Table 2 and Figure 5), 2 kV is typically specified for industrial data/signal lines, and EFT bursts are specified as repeated pulses/bursts for 15 ms with each single pulse 5 × 50 ns. In IEC 61000-4-5 surge testing (Table 4), Req = 2 Ω models low-voltage power mains (giving 250 A at 500 V Class 1, 500 A at 1 kV Class 2, 1000 A at 2 kV Class 3, and 2000 A at 4 kV Class 4), Req = 12 Ω (2 Ω CWG + 10 Ω coupling) models mains-to-ground, and Req = 42 Ω (2 Ω CWG + 40 Ω coupling) models data lines to ground (giving 12 A, 24 A, 48 A, and 96 A).

To comply with the RS-485 specified common-mode voltage range of -7V to 12V, TVS stand-off voltages should be VWM >= 12V, and maximum clamp voltages range from 25V up to 35V versus the 14V maximum bus voltage of a standard transceiver. For transceivers specified with low ESD immunity, it may be necessary to reduce the remaining current flowing into the transceiver through series resistors; common values range from 10 Ω to 20 Ω. The TPD3F303 integrates a three-channel C-R-C low-pass EMI filter (47-Ω clock termination resistor, 100-Ω data and reset termination resistors, -3-dB bandwidth 300 MHz) with ±15-kV contact and ±15-kV air-gap IEC 61000-4-2 Level 4 ESD protection and 6 V minimum DC breakdown voltage. On the checked HARTING hood 19 40 004 0410 (size 4 B, net weight 159 g), the limiting temperature is -40 to +125 °C according to IEC 61984, and the IP code is IP65, IP68 (IEC 60529), and IP69/IPX9K (ISO 20653).

Transient Standard or Interface Scope Coupling Network, Voltage, or Resistor Range Specified Pulse Profile or Clamping Requirement
In IEC 61000-4-4 EFT testing (Table 2 and Figure 5) 2 kV is typically specified for industrial data/signal lines and EFT bursts are specified as repeated pulses/bursts for 15 ms with each single pulse 5 × 50 ns.
In IEC 61000-4-5 surge testing (Table 4) Req = 2 Ω models low-voltage power mains (giving 250 A at 500 V Class 1, 500 A at 1 kV Class 2, 1000 A at 2 kV Class 3, and 2000 A at 4 kV Class 4), Req = 12 Ω (2 Ω CWG + 10 Ω coupling) models mains-to-ground and Req = 42 Ω (2 Ω CWG + 40 Ω coupling) models data lines to ground (giving 12 A, 24 A, 48 A, and 96 A).
To comply with the RS-485 specified common-mode voltage range of -7V to 12V TVS stand-off voltages should be VWM >= 12V and maximum clamp voltages range from 25V up to 35V versus the 14V maximum bus voltage of a standard transceiver.
For transceivers specified with low ESD immunity it may be necessary to reduce the remaining current flowing into the transceiver through series resistors common values range from 10 Ω to 20 Ω.

Pre-Tapeout ESD Protection Verification Checklist

  • The voltage presented to the node Protected Line is VESD = Vbr(TVS) + IESD * RDYN(TVS) + (L2 + L3)(dIESD/dt), so the PCB designer needs to minimize L3 and eliminate L2.
  • IESD can be steered towards the TVS by making L4 much larger than L1 (L4 >> L1), accomplished by placing the TVS as near to the ESD Source as PCB design rules allow while placing the Protected IC far away.
  • In Case 1, there is no VIA between the ESD Source and the TVS so IESD is forced to the TVS protection pin before the VIA (representing L4 in Figure 2-1), whereas in Case 2 the VIA represents L2 and increases voltage at the Protected IC by LVIA(dIESD/dt).
  • In Table 3-1, an exposed thermal pad (EP) lowers impedance to ground to help dissipate large ESD currents, though some bidirectional TVS devices require the thermal pad to be floating; for a VCC pin, a 0.1-µF ceramic capacitor is recommended between the VCC trace and the VCC pin on the diode.

Sources

  • International Electrotechnical Commission — Electrostatic Discharge Immunity Test Publication
  • STMicroelectronics — Application Note on PCB Layout and ESD Protection
  • Texas Instruments — ESD Packaging and Layout Guide
  • Texas Instruments — Analog Applications Journal on System-Level ESD Protection
  • Texas Instruments — Technical Brief on TLP Current and ESD Clamping
  • Texas Instruments — ESD Layout and System Design Guide
  • Texas Instruments — Application Report on IEC Transient Immunity Tests
  • Texas Instruments — Application Report on Industrial Differential Bus Transient Protection
  • Texas Instruments — High-Speed ESD Protection Array Datasheets