Reliable printed circuit board power and field-wiring interfaces depend on coordinating current-temperature derating, pin-to-pin creepage and clearance, and gas-tight conductor termination before locking the board footprint. IEC 60947-7-4:2019 specifies requirements for PCB terminal blocks mounted on the printed circuit board by soldering, press-in or equivalent methods. Under DIN EN 60512-5-1 and DIN EN 60512-5-2, the base curve assumes a 100°C upper limiting temperature of the insulation material, and the permissible load current on the derating curve is 0.8 times the respective base current.
IEC 60947-7-4 Scope and Current-Temperature Derating Curves
Selecting terminal blocks for industrial electronics requires matching conductor cross-section capacity, thermal derating curves, and insulation spacing to the target installation environment. IEC 60947-7-4:2019 applies to PCB terminal blocks connecting copper conductors with a cross-section between 0.08 mm² and 300 mm² (AWG 28 to 600 kcmil). IEC 60947-7-4:2019 applies to PCB terminal blocks intended for circuits with a rated voltage not exceeding 1000 V AC up to 1000 Hz or 1500 V DC, and replaces the first edition published in 2013. IEC 60947-7-4:2019 Edition 2.0 was published on 2019-01-18, has 71 pages, and lists a stability date of 2027. IEC 60947-7-4:2019 places screw tightening torques in Table 4 (previously in Table 4 of IEC 60947-1:2007) and clarifies the temperature-rise test (current-temperature derating) according to Figure 4.
| Standard or Manufacturer Test Method | Mounting Arrangement or Conductor Scope | Permissible Temperature Rise or Derated Current |
|---|---|---|
| DIN EN 60512-5-1 / DIN EN 60512-5-2 | 100°C upper limiting insulation temperature base curve | Permissible load current = 0.8 × base current |
| IEC 60947-7-1/-2 temperature-rise test | 5 horizontal rail blocks in series with 1 or 2 m loops (approx. +20°C room) | Max 45 K rise at the middle terminal block |
| UL 1059 temperature-rise test | 3 adjacent horizontal terminal blocks (25°C ambient) | Max 30 K temperature rise |
| IEC 61984 voltage-drop test | 0.1 × rated cross-section current capacity (approx. 20°C) | <= 3.2 mV per block and <= 1.5 × initial reading |
For plug-in terminal blocks from Phoenix Contact tested under DIN EN 60512-5-2, derating curves with 2-, 5-, 10-, and 15-position arrangements are specified. In the Phoenix Contact HEAVYCON de-rating curve example tested to DIN EN 61984 and DIN EN 60512-5-1 (with 20% of the maximum current deducted), at 40°C ambient temperature the maximum safe current is 40A with 6mm² cable, about 31A with 4mm² cable, and 24A with 2.5mm² cable. In the Phoenix Contact HEAVYCON de-rating curve for a 6mm² cable, increasing ambient temperature from 40°C to 60°C reduces the maximum current from 40A to 34A, and an 80°C ambient temperature reduces it to 26A (allowing 35A up to 55°C).
Temperature-Rise Limits and Contact Voltage-Drop Verification
In the IEC 60947-7-1/-2 temperature-rise test, five terminal blocks are horizontally mounted on a rail and connected in series with 1 or 2 m conductor loops; at a room temperature of about +20°C, a maximum temperature rise of 45 K is permitted at the middle terminal block. In the UL 1059 temperature-rise test, three terminal blocks are horizontally mounted adjacent to one another; at an ambient temperature of 25°C, a maximum temperature rise of 30 K is permitted. Same Sky states that it is best practice to use a terminal block rated for at least 150% of the maximum current expected in the system, and lists common industry pitches of 2.54 mm, 3.81 mm, 5.0 mm, and 7.62 mm. In the IEC 61984 voltage-drop test, a direct test current of 0.1 times the rated cross-section current carrying capacity is applied at about 20°C, and the voltage drop must not exceed 3.2 mV per terminal block nor exceed 1.5 times the value measured at the start of the test. Phoenix Contact’s voltage-drop test table lists rated current carrying capacities by conductor cross-section: 0.2 mm² (24 AWG) = 4 A; 0.5 mm² = 6 A (20 AWG = 8 A); 0.75 mm² = 9 A (18 AWG = 10 A); 1 mm² = 13.5 A; 1.5 mm² = 17.5 A (16 AWG = 16 A); 2.5 mm² = 24 A (14 AWG = 22 A); 4 mm² = 32 A (12 AWG = 29 A); 6 mm² = 41 A (10 AWG = 38 A).
Pitch Selection, Creepage, Clearance, and UL 1059 Use Groups
Creepage is the shortest distance along the surface of a solid insulation material between two conductive parts, dimensioned for a pollution degree, material group, and root-mean-square (RMS) working voltage. Clearance is the shortest distance in air between two conductive parts, dimensioned to prevent air ionization or arcing during transient overvoltage, with a multiplication factor for altitudes greater than 2,000 m. Creepage handles long-term steady-state working voltages while clearance handles short-term transients of a few milliseconds or less, and the creepage distance cannot be less than the clearance distance.
The comparative tracking index (CTI) rating is the maximum voltage an insulating material withstands with less than 0.5 A of tracking current when tested with 50 drops of water contaminated with 0.1% ammonium chloride. Insulating material groups based on CTI (VRMS) are Group I (600 <= CTI), Group II (400 <= CTI < 600), Group IIIa (175 <= CTI < 400), and Group IIIb (100 <= CTI < 175), with most PCB FR4 materials rated for Material Group IIIa. Pollution degree 1 applies to sealed systems or PCBs with conformal coating; Pollution degree 2 applies where occasional condensation causes temporary conductivity (labs, offices, server/telecom enclosures); Pollution degree 3 applies where conductive pollution or condensation-induced conductivity occurs (industrial applications, unheated factory rooms). IEC 60664-1 is the foundational standard for user safety in an insulation system and applies to systems up to 1.5 kVDC or 1 kVAC, whereas IPC-2221B and IPC-9592B address functional PCB spacing only.
IEC 60664-1 Impulse Clearance and Pollution Degree 3 Creepage
Under IEC 60664-1 Overvoltage Category III (the default category for terminal blocks in fixed installations), neutral conductor voltages of 300 V, 600 V, and 1000 V correspond to rated impulse withstand voltages of 4000 V, 6000 V, and 8000 V. Under IEC 60664-1 condition A (inhomogeneous field) across Pollution Degrees 1, 2, and 3, required impulse withstand voltages of 4000 V, 5000 V, 6000 V, and 8000 V require minimum clearances of 3.0 mm, 4.0 mm, 5.5 mm, and 8.0 mm respectively. For Pollution Degree 3, minimum creepage distances for Insulation Material Groups I, II, and III are: 6.3 mm, 7.1 mm, and 8.0 mm at 500 V RMS; 8.0 mm, 9.0 mm, and 10.0 mm at 630 V RMS; 10.0 mm, 11.0 mm, and 12.5 mm at 800 V RMS; and 12.5 mm, 14.0 mm, and 16.0 mm at 1000 V RMS.
UL 1059 Use Groups A Through E and UL 840 Spacer Rules
Under UL 1059, Use Group A (service power circuits, dead-front switchboards, panelboards) requires minimum spacings in inches (mm) through air and over surface of 1/2 in (12.7 mm) and 3/4 in (19.1 mm) at 51–150 V, 3/4 in (19.1 mm) and 1-1/4 in (31.8 mm) at 151–300 V, and 1 in (25.4 mm) and 2 in (50.8 mm) at 301–600 V. Under UL 1059, Use Group B (commercial appliances, business equipment, electronic data processing equipment) requires minimum spacings in inches (mm) through air and over surface of 1.6 mm at 51–150 V, 2.4 mm at 151–300 V, and 3/8 in (9.5 mm) through air / 1/2 in (12.7 mm) over surface at 301–600 V. Under UL 1059, Use Group C (general industrial) requires minimum spacings in inches (mm) through air and over surface of 3.2 mm and 1/4 in (6.4 mm) at 51–150 V, 1/4 in (6.4 mm) and 3/8 in (9.5 mm) at 151–300 V, and 3/8 in (9.5 mm) and 1/2 in (12.7 mm) at 301–600 V. Under UL 1059, Use Group D (industrial devices having limited ratings) requires minimum spacings in inches (mm) of 1.6 mm through air and 3.2 mm over surface at 51–300 V, and 4.8 mm through air and 3/8 in (9.5 mm) over surface at 301–600 V, where single-circuit load does not exceed 15 amperes at 51–150 volts, 10 amperes at 151–300 volts, or 5 amperes at 301–600 volts. Under UL 1059, Use Group E (terminal blocks rated 601–1500 V) requires minimum spacings of 0.55 in (14.0 mm) through air and 0.85 in (21.6 mm) over surface at 601–1000 V, and 0.70 in (17.8 mm) through air and 1.20 in (30.5 mm) over surface at 1001–1500 V; slots or air spaces of 0.013 inch (0.33 mm) or less are disregarded. Under UL 1059 Note a, the spacing between field wiring terminals of opposite polarity and between a field wiring terminal and a grounded dead metal part shall not be less than 1/4 inch (6.4 mm) if short-circuiting or grounding may result from projecting strands of wire. WAGO 2606 Series 12.5 mm-pitch PCB terminal blocks are rated for 800–1,000 V operation per IEC/EN 60664-1 vs 600 V per UL 1059 and CSA-C22.2 No. 158 (or 1,000 V under UL 1059 when equipped with spacers, or evaluated under UL 840 in UL 508 and UL 508C end-use equipment).
| Insulation Standard or Use Group Classification | Application Scope or Field Condition | Required Clearance Through Air and Creepage Over Surface |
|---|---|---|
| IEC 60664-1 Condition A (Pollution Degrees 1–3) | Inhomogeneous field at 4,000 / 5,000 / 6,000 / 8,000 V impulse | Minimum clearance: 3.0 / 4.0 / 5.5 / 8.0 mm |
| UL 1059 Use Group A | Service power circuits, dead-front switchboards, panelboards | 12.7 / 19.1 mm (51–150 V), 19.1 / 31.8 mm (151–300 V), 25.4 / 50.8 mm (301–600 V) |
| UL 1059 Use Group C | General industrial equipment | 3.2 / 6.4 mm (51–150 V), 6.4 / 9.5 mm (151–300 V), 9.5 / 12.7 mm (301–600 V) |
Screw vs Push-In Spring Clamping and Stranded Wire Termination
When a stranded copper wire is solder-dipped (tinned), the tin flows into the small spaces between the copper strands, turning the copper wire and tin into a solid mass; when compressed in a screw terminal cage, the tin can fracture, pull strands apart, create voids, and loosen the wire. During thermal cycling in a screw terminal block, tin expands more than the copper cage due to its coefficient of thermal expansion; upon cooling and shrinking, the tinned wire changes shape and is no longer properly clamped or gas-tight, so Phoenix Contact U004008A recommends using ferrules and proper screw torque instead. Same Sky TB001-500 is a horizontal interlocking PCB terminal block with a 5.0 mm pitch, 2 to 24 poles, PA66 (UL94V-0) housing, UL 1059 rating of 300 V and 15 A (for 22–12 AWG wire), and IEC (EN 60998-1:2004, EN 60998-2-1:2004) rating of 250 V and 24 A (for 2.5 mm² wire). Same Sky TB001-500 specifies an M3 screw size, 0.5 N·m screw torque, 5–6 mm strip length, maximum 20 mΩ contact resistance, minimum 500 MΩ insulation resistance at 500 Vdc, 2500 Vac withstanding voltage, 4000 V surge voltage, and -40 to 105 °C operating temperature. Same Sky TB001-500 specifies a wave soldering temperature of 255 to 265 °C (260 °C typical) for a maximum of 5 seconds, and a hand soldering temperature of 345 to 355 °C (350 °C typical) for a maximum of 10 seconds.
Same Sky TB0015-500 is a push-button PCB terminal block with a 5.0 mm pitch, 2 to 12 poles, PA66 (UL94V-0) housing, UL 1059 rating of 300 V and 10 A in Use Group B and D (for 30–16 AWG wire), and IEC (IEC 60947-7-4, IEC 60998-2-2) rating of 320 V and 17.5 A in Overvoltage Category/Pollution Degree III/2 (for 0.2–1.5 mm² wire). Same Sky TB0015-500 specifies a 9–10 mm strip length, maximum 8 mΩ contact resistance, 2,500 Vac withstanding voltage for 1 minute, 4,000 V surge voltage, -40 to 105 °C operating temperature, and a wave soldering profile of 255 to 265 °C (260 °C typical) for a maximum of 3 seconds. The Same Sky TB0015-500 family includes the TB0015-500 single-deck version, the TB0015-500-2 double-deck version, and the TB0015-500-3 triple-deck version.
Commercial Screw, Push-In, Lever, and Pluggable Terminal Block Specifications
Phoenix Contact MKDS 3/ 3-5,08 (part 1711738) is a 3-position wave-soldering PCB terminal block with a 5.08 mm pitch, 1.3 mm hole diameter, 5 mm solder pin length, 18 mm height, M3 screw thread, 0.5 Nm to 0.6 Nm tightening torque, and 8 mm stripping length. Phoenix Contact MKDS 3/ 3-5,08 (1711738) has Insulating material group I (PA, UL 94 V0), 4 kV rated surge voltage, EN-VDE rated voltages of 250 V (III/3), 400 V (III/2), and 630 V (II/2), nominal current IN of 24 A at 2.5 mm² nominal cross section, and maximum load current of 28 A with a 4 mm² conductor cross section. Phoenix Contact MKDS 3/ 3-5,08 (1711738) accepts single conductors of 0.2 mm² to 4 mm² solid, 0.2 mm² to 2.5 mm² flexible, 0.25 mm² to 2.5 mm² flexible with ferrule (with or without plastic sleeve), or 24 to 12 AWG. For 2 conductors with the same cross section, Phoenix Contact MKDS 3/ 3-5,08 (1711738) accepts 0.2 mm² to 1.5 mm² solid or stranded, 0.25 mm² to 0.75 mm² stranded with ferrules without plastic sleeve, or 0.5 mm² to 1.5 mm² stranded with TWIN ferrules with plastic sleeve. Under cULus Recognized (file E60425-19770427), Phoenix Contact MKDS 3/ 3-5,08 (1711738) is rated for 300 V and 15 A in Use Group B and 300 V and 10 A in Use Group D for 30-12 AWG; under CSA (13631), it is rated for 300 V and 10 A in Use Groups D and B for 28-12 AWG.
WAGO 2624 Series PCB terminal blocks with Push-in CAGE CLAMP® are rated per IEC/EN 60664-1 for 32 A and 0.2 to 6 mm² conductors (0.25 to 2.5 mm² with ferrule, 24 to 10 AWG, 10 to 12 mm strip length), with voltage ratings by pin spacing: at 5 mm: 320 V (III/3), 400 V (III/2), 630 V (II/2), 4 kV surge; at 7.5 mm: 630 V (III/3, III/2), 1000 V (II/2), 6 kV surge, UL 1059 Use Group C 150 V / 26 A; at 11.5 mm: 1000 V (III/3, III/2, II/2), 8 kV surge, UL 1059 Use Group C 600 V / 26 A. WAGO 2604 Series lever-equipped PCB terminal blocks with Push-in CAGE CLAMP® are rated per IEC/EN 60664-1 for 32 A and 0.2 to 4 mm² conductors (0.25 to 2.5 mm² with ferrule, 24 to 12 AWG, 9 to 11 mm strip length), with UL 1059 Use Group C ratings of 300 V / 20 A at 7.5 mm pin spacing and 600 V / 20 A at 11.5 mm pin spacing. WAGO 2626 Series PCB terminal blocks at 7.5 mm pin spacing are rated per IEC/EN 60664-1 for 41 A, 800 V (III/3), 1000 V (III/2 and II/2), and 8 kV surge voltage for 0.2 to 10 mm² solid or fine-stranded conductors (0.25 to 6 mm² with ferrule, 24 to 8 AWG, 13 to 15 mm strip length). WAGO 2601 Series is a super-compact, tool-free PCB terminal block with lever technology and Push-In Cage Clamp connection technology, featuring a 3.5 mm pin spacing for solid and fine-stranded conductors with ferrules from 26 to 14 AWG. Phoenix Contact SPTH 1.5 Push-in PCB Terminal Blocks offer large test openings, a connection capacity of up to 2.5 mm², and an identical footprint that allows switching between screw and push-in connection technology without adapting the PCB layout or device housing. Phoenix Contact GSMSTB 2.5 Pluggable Terminal Blocks operate at a 7.62 mm pitch in 2 to 12 position variants, are compatible with GMSTB 2.5, GIC 2.5, and GMSTBV 2.5 headers, and offer a UL voltage rating of 300 V and a UL current rating of 15 A.
| Commercial Terminal Block Series | Pitch, Clamping Mechanism, and Mechanical Profile | Electrical Ratings and Conductor Cross-Section Capacity |
|---|---|---|
| Same Sky TB001-500 | 5.0 mm pitch horizontal interlocking screw block, 2–24 poles, PA66 (UL94V-0) | UL 1059: 300 V / 15 A (22–12 AWG); EN 60998: 250 V / 24 A (2.5 mm²) |
| Phoenix Contact MKDS 3/ 3-5,08 (1711738) | 5.08 mm pitch, 3-pos wave-solder M3 screw block, PA Group I (UL 94 V0) | EN-VDE: 250 V (III/3), 400 V (III/2), 630 V (II/2), 4 kV surge; 24 A at 2.5 mm² (max 28 A at 4 mm²) |
| WAGO 2626 Series (7.5 mm pin spacing) | 7.5 mm pitch Push-in CAGE CLAMP®, 13–15 mm strip length | IEC/EN 60664-1: 41 A, 800 V (III/3), 1000 V (III/2, II/2), 8 kV surge; 0.2–10 mm² (24–8 AWG) |
| WAGO 2601 Series | 3.5 mm pitch compact tool-free lever Push-In Cage Clamp | Solid and fine-stranded conductors with ferrules from 26 to 14 AWG |
Sizing PCB Terminal Blocks for DIN Rail Power Supplies and Isolated DC/DC Converters
Where off-board power cables transition from enclosure wall feedthroughs and heavy-duty industrial connectors onto the printed circuit board, terminal spacing and isolation barriers must coordinate across the entire power path. Under IEC 60950-1 / IEC 62368-1 energy-source classifications, Energy source class 1 (ES1 / SELV) covers circuits up to 60 V, ES2 covers 60 V to 120 V (requiring basic isolation), and ES3 covers voltages above 120 V (requiring reinforced isolation). Teltonika PR327NP0 DIN Rail Power Supply delivers a 48VDC output voltage and 120W output power with a 2.5A output current via screw-terminal input and output connections, supporting 100V AC to 240V AC (50Hz/60Hz) input and a 4242V DC dielectric withstand voltage between primary and secondary circuits. CUI Inc DQD30 DC/DC Converters are 30W single-regulated output isolated DC/DC converters with 1500VDC isolation voltage, operating over a -40°C to +105°C temperature range in a 1“ x 1“ case with a DIP6 footprint and available in PCB, chassis, and DIN-rail mounting options.
Pre-Layout PCB Terminal Block Sizing Checklist
- Verify current derating at enclosure ambient: Apply the 0.8 derating factor under DIN EN 60512-5-1/-2 (and multi-pole thermal derating curves up to 60–80°C) while keeping at least the 150% nominal current headroom recommended by Same Sky.
- Check field-wiring strand clearance: Maintain at least 1/4 in (6.4 mm) between opposite-polarity field terminals and grounded dead metal wherever stray wire strands could bridge the gap (UL 1059 Note a).
- Mandate crimped ferrules over solder tinning: Specify ferrule-crimped fine-stranded wire and calibrated screw torque (such as 0.5–0.6 N·m on M3 cages) rather than solder-tinned wire ends.
- Confirm single- vs dual-conductor cage windows: Cross-check solid, bare flexible, single-ferrule, and TWIN-ferrule cross-section limits on the target part datasheet before finalizing BOM wire gauges.
Sources
- International Electrotechnical Commission — Low-Voltage Switchgear and Controlgear Terminal Blocks Specification
- Texas Instruments — Application Note on Creepage and Clearance in Power Supply Systems
- Phoenix Contact — Technical Guide to Electrical Tests for Terminal Blocks
- Phoenix Contact — Engineering Note on Connector Derating Curves
- Phoenix Contact — Technical White Paper on Tinning Stranded Wires and Ferrule Termination
- Phoenix Contact — Printed Circuit Board Terminal Block and Pluggable Connector Datasheets
- Same Sky — Engineering Guide to Terminal Block Selection and Series Datasheets
- WAGO — Printed Circuit Board Terminal Blocks and Pluggable Connectors Technical Catalog
- WECO Electrical Connectors — Industrial Terminal Block Spacing Specification Reference
- Teltonika Networks — Industrial Power Supply Technical Datasheet
- CUI Inc — Isolated Board-Mount Power Converter Technical Datasheet